Encryption device cannot match with Solarman P1, and RJ45 device is not supported.
readerFind your smart meter compatibility, version, P1 port location and if it requires a power adapter. Can’t find your meter? Click here to qualify for a free P1 Meter Reader!
The location of the checkmark on meter images shows you where the P1 port is located on each meter. In most cases, the port is behind a latch or cap.
Suitable electricity meter model
| P1 Meter Reader Compatibility List | |||
| Model | P1-2W | New products (P1-2W-C) |
|
| Iskra MT382 | √ | /ISk5\ | |
| Iskra ME382 | |||
| Iskra AM550 | √ | ||
| Kaifa MA105 | √ | KFM5KAIFA KFM5- METER |
|
| Kaifa MA105A | |||
| Kaifa MA105C | √ | ||
| Kaifa MA105H2CNL | |||
| Kaifa MA304C | √ | ||
| Kaifa MA304H4CNL | √ | ||
| Kaifa MA304 | × | √ | |
| Kaifa MA304 E0079 | √ | ||
| Kaifa MA309M | |||
| Kaifa MA304H4E | |||
| Kaifa MA304H4D | |||
| Kamstrup HAN-NVE module | /KMP5 | ||
| Kamstrup HAN-P1 module | |||
| Kamstrup Omnia e-meter three-phase | |||
| Kamstrup 162JxC | |||
| Kamstrup 382JxC | |||
| Sagemcom XS210 | /Ene5 | ||
| Sagemcom XS212 | |||
| Sagemcom T211 | √ | ||
| Sagemcom T210-D-r | |||
| Sagemcom T210-D | √ | ||
| Sagemcom XT211 | |||
| Sagemcom S211 | √ | ||
| ZIV ESMR5 M21 | √ | ||
| ZIV ESMR5 M25 | √ | ||
| Landis+Gyr E360-1P | XEMEX XMX5LGBBFG10127 XMX5LGBBFG10126 XMX5LGBBFFB2311 |
||
| Landis+Gyr E360-3P | × | √ | |
| Landis+Gyr E360 | √ | ||
| Landis+Gyr E350 | × | √ | |
| Landis+Gyr E450 | |||
| Aidon 7410P | √ | ||
| Aidon 6483SE | |||
| NES 83335 | √ | ||
| Sanxing SX631 | |||
NL Netherlands
Please notice : encryption device cannot match with Solarman P1, and RJ45 device is not supported.
Compatible

Under verification

LT Lithuania
Modern meters in Lithuania have a P1 port and work with the P1 Meter Reader. The data frequency is limited to once per minute.
Under verification

SE Sweden
All modern meters in Sweden have a P1 or HAN port and are compatible with the P1 Meter Reader. In some cases you may need to contact your network operator to enable the HAN port on your smart meter.
Under verification


HU Hungary
All modern meters in Hungary (also known as Okosmérő) have a P1 port but not all are compatible with the P1 Meter Reader. This is dependent on your network operator.
Under verification

FI Finland
Modern meters in Finland have a P1 port (also known as HAN port) and work with the P1 Meter Reader. In some cases the P1 port can be disabled and you need to contact your network operator to enable the P1 port on your smart meter.
Compatible

Under verification

BE Belgium
All modern meters (also known as “digitale meter”) in Belgium have a P1 port and are compatible with the P1 Meter Reader. By default, the P1 port on Belgian smart meters is deactivated for security and privacy of your data. Your local network operator can activate this port.
Under verification

LU Luxembourg
All modern meters (also known as “Smarty”) in Luxembourg have a P1 port and are compatible with the P1 Meter Reader. By default, the P1 port on Luxembourg “Smarty” meters is encrypted.
Under verification

DK Denmark
In Denmark, smart meters are available with a P1 port, a HAN port and a HEP port. If you have a P1 port, you can use the P1 Meter Reader. If you have a HAN port, you will need an extra HAN converter to get the P1 Meter Reader to work. Our products do not work with the HEP port.
Under verification

AT Austria
In Austria it is network operator dependant if your smart meter has a P1 port. By default the P1 port is encrypted.
Under verification

NO Norway
All modern meters in Norway have a HAN port and are compatible with the P1 Meter Reader.
If you don't have access to your HAN port, you may need to contact your network operator to enable the HAN port on your smart meter.
Under verification




Smart Energy Monitor: Opening a New Era of Energy Management
How to Use the P1 Meter Reader?
2 comments
Hello,
can we make it compatible for Swiss Meters?
Thanks for checking and Feedback me.
Best Regards
Benjamin
Solarman Smart is now engaged with Sofar inverter.